Pressure drop in a natural gas pipe by the Darcy–Weisbach method: density from pressure, what to enter, a 5 km worked example and the limits of the method.
The pressure drop in a natural gas line depends on the gas flow, the pipe diameter, the length, the roughness and the gas density — and the density itself depends on the line pressure. This guide shows the Darcy–Weisbach method used by the Line Sizing calculator, with the gas density taken at the inlet pressure.
ρ = P · MW / (Z · R · T)
ΔP = f · (L / D) · (ρ · v² / 2)
The gas is treated as flowing at constant density and temperature (isothermal). That is accurate while the pressure drop is a small part of the inlet pressure — the usual limit is about 10 %. If the drop is larger the density falls along the pipe and the result is optimistic.
Natural gas at 40 bar absolute and 15 °C (molecular weight 17.4, Z = 0.90, viscosity 11 µPa·s), 15 kg/s — about 73,000 m³/h at 15 °C and 1 atm — through 5 km of commercial steel pipe (roughness 0.045 mm). Density at the inlet is 32.3 kg/m³.
| Inside diameter (mm) | Velocity (m/s) | Pressure drop (bar) | Share of inlet pressure |
|---|---|---|---|
| 250 | 9.47 | 3.95 | 9.9% |
| 300 | 6.57 | 1.54 | 3.8% |
| 350 | 4.83 | 0.696 | 1.7% |
| 400 | 3.7 | 0.35 | 0.88% |
The 250 mm candidate loses 3.95 bar, 9.9% of the inlet pressure — at the edge of the method's range, so do not rely on it. 300 mm loses 1.54 bar (3.8%), well inside the range. Each step up in diameter cuts the loss sharply because pressure drop falls roughly with the 5th power of the diameter at constant flow. The velocities here are below the 15–30 m/s of plant process gas lines because the line is long and the pressure-drop budget governs.
Run your own numbers — pick a pipe size and see velocity and pressure drop instantly. Open the Line Sizing calculator
Results are for reference and preliminary checks; a qualified engineer must verify them before use. Read the disclaimer