Size pump discharge and suction lines: velocity and pressure-drop ranges, why the suction line is larger, and a worked example for 150 m³/h of water.
A pump line is sized twice: the discharge line for velocity and pressure drop, and the suction line much more conservatively. The suction line must be short and large because its pressure drop reduces the pressure available at the pump inlet, which is what protects the pump from cavitation.
| Line | Velocity (m/s) | Pressure drop (bar / 100 m) |
|---|---|---|
| Pump suction | 0.5–1.5 | ≤ 0.05 |
| Pump discharge | 1.5–3.0 | ≤ 0.5 |
The friction loss of the discharge line is one term of the pump head: pump head = static head + friction loss + the pressure needed at the destination. A line that is too small raises the head the pump must produce and the power it uses.
Water at 150 m³/h (density 998 kg/m³, viscosity 1.0 mPa·s) through 100 m of commercial steel pipe (roughness 0.045 mm). The inside diameters are trial values.
| Inside diameter (mm) | Velocity (m/s) | Pressure drop (bar / 100 m) |
|---|---|---|
| 100 | 5.31 | 2.44 |
| 125 | 3.4 | 0.783 |
| 150 | 2.36 | 0.311 |
| 200 | 1.33 | 0.0735 |
| 250 | 0.849 | 0.0243 |
Discharge: 150 mm gives 2.36 m/s and 0.311 bar per 100 m and passes. 125 mm is too fast (3.4 m/s) with 0.783 bar per 100 m, and 200 mm falls below the 1.5 m/s minimum (1.33 m/s).
Suction: 200 mm meets the velocity range (1.33 m/s) but loses 0.0735 bar per 100 m, above the 0.05 bar limit. 250 mm gives 0.849 m/s and 0.0243 bar per 100 m and passes. The suction line ends up one or two sizes larger than the discharge line — normal practice.
Run your own numbers — pick a pipe size and see velocity and pressure drop instantly. Open the Line Sizing calculator
Results are for reference and preliminary checks; a qualified engineer must verify them before use. Read the disclaimer