Two-Phase Line Sizing

한국어로 보기

Size a gas–liquid line: the Lockhart–Martinelli method with the Chisholm correlation, flow pattern and erosion checks, and a worked example.

When gas and liquid flow together in one pipe the pressure drop is far larger than for either phase alone, and the flow pattern — annular, slug, stratified — decides whether the line vibrates or erodes. Two-phase lines are sized on pressure drop, a flow-pattern check and an erosional velocity limit.

The Lockhart–Martinelli method

The Line Sizing calculator uses the Lockhart–Martinelli approach with the Chisholm correlation. First calculate the pressure drop each phase would cause flowing alone in the pipe, (dP/dL)L and (dP/dL)G, with the Darcy–Weisbach equation. Then:

X² = (dP/dL)L / (dP/dL)G

ΦL² = 1 + C / X + 1 / X²

ΔP two-phase = ΦL² · ΔP liquid alone

The Chisholm constant C depends on whether each phase alone would be turbulent or laminar: C = 20 when both are turbulent, 12 for laminar liquid with turbulent gas, 10 for turbulent liquid with laminar gas, and 5 when both are laminar.

Flow pattern and erosion

The calculator classifies the flow pattern with the Baker map for horizontal flow, and also reports pattern maps by Mandhane, Taitel–Dukler and Griffith–Wallis. Slug flow produces surging and vibration, so lines in slug flow need careful support. The mixture velocity should also stay below the erosional velocity limit from API RP 14E, which the calculator checks.

Worked example — liquid and gas in one line

Liquid 8 kg/s (density 800 kg/m³, viscosity 1.0 mPa·s) and gas 2 kg/s (density 20 kg/m³, viscosity 12 µPa·s), surface tension 0.02 N/m, 100 m of commercial steel pipe (roughness 0.045 mm). The inside diameters are trial values; velocities are superficial (each phase as if alone).

Inside diameter (mm)Liquid velocity (m/s)Gas velocity (m/s)XΦL²Pressure drop (bar / 100 m)Flow pattern
1001.2712.70.69631.84.16Annular
1500.5665.660.73130.20.536Annular
2000.3183.180.75929.10.127Slug
2500.2042.040.78128.20.042Slug

The two-phase pressure drop is about 30 times the liquid-alone value (ΦL² of 31.8 down to 28.2). The 100 mm candidate loses 4.16 bar per 100 m with a gas velocity of 12.7 m/s. 150 mm cuts that to 0.536 bar and stays in annular flow; 200 mm moves the line into slug flow, which may be acceptable on pressure drop but needs a vibration check.

Run your own numbers — pick a pipe size and see velocity and pressure drop instantly. Open the Line Sizing calculator

More guides