Drum Volume Calculation: Vertical and Horizontal Drums

한국어로 보기

How to calculate drum volume: shell and 2:1 head formulas, liquid volume at any level in vertical and horizontal drums, retention time and worked examples.

Process drums — separators, knock-out drums, reflux drums and surge drums — are sized first on volume: the total volume of the vessel, and the liquid volume held between the control levels. That liquid volume, divided by the flow through the drum, is the retention time (also called hold-up time), and it is usually the number the process design asks for.

Parts of a drum

Total volume

The shell is a cylinder, and one 2:1 semi-ellipsoidal head holds the volume of half an ellipsoid of revolution:

V shell = π · D² · L / 4

V head = π · D³ / 24

V total = π · D² · L / 4 + π · D³ / 12

Liquid volume in a vertical drum

In a vertical drum the liquid fills the bottom head first, then rises straight up the shell. With the level h measured from the bottom tangent line, every millimetre of level inside the shell adds the same volume, so the liquid volume is the full bottom head plus a cylinder of height h:

V liquid = π · D³ / 24 + π · D² · h / 4

Below the bottom tangent line, and above the top tangent line, the level is inside a head and the volume follows the ellipsoid shape instead of a straight line.

Liquid volume in a horizontal drum

In a horizontal drum the wetted cross-section is a circular segment, so volume does not rise in step with level. Each millimetre near the centre line holds much more liquid than a millimetre near the bottom or the top. For a level h measured from the bottom of the drum and radius R = D / 2, the wetted area of the shell is:

A = R² · acos((R − h) / R) − (R − h) · √(2 · R · h − h²)

The liquid in the shell is A · L. The liquid in each head is found by adding up thin slices across the head depth; the Drum Volume calculator does this numerically with Simpson’s rule, then adds both heads to the shell volume.

Liquid levels and retention time

A drum usually carries five control levels. Retention time between two levels is the liquid volume between them divided by the flow:

t (min) = V (m³) / Q (m³/h) × 60

Worked example — horizontal drum

Inside diameter 2000 mm, T-T length 6000 mm, 2:1 semi-ellipsoidal heads, liquid flow 20 m³/h. Total volume is 20.94 m³. Levels are measured from the bottom of the drum.

Level from bottom (mm)Liquid volume (m³)Retention time (min)
5004.01212.04
100010.4731.42
150016.9350.8

At 1/2 of the diameter the drum holds exactly half its volume. At 1/4 of the diameter (500 mm) holds only 19% of the total volume, and at 3/4 (1500 mm) holds 81%. Reading levels as straight percentages of volume would put the alarm levels in the wrong place.

Worked example — vertical drum

Inside diameter 1500 mm, T-T length 4000 mm, liquid flow 10 m³/h. Total volume is 7.952 m³. Levels are measured from the bottom tangent line.

Level from bottom tangent line (mm)Liquid volume (m³)Retention time (min)
00.44182.651
10002.20913.25
25004.8629.16

At the bottom tangent line the drum already holds the bottom head, 0.442 m³. From there every 1000 mm of level adds 1.77 m³, which at 10 m³/h is 10.6 minutes of retention.

Enter your drum size and liquid levels to get volumes and retention times at every level. Open the Drum Volume calculator

More guides

Results are for reference and preliminary checks; a qualified engineer must verify them before use. Read the disclaimer