Pipe Sizing: Velocity and Pressure Drop Method

한국어로 보기

How to size a pipe: check velocity and pressure drop, typical design ranges for liquid lines, and a worked example with trial inside diameters.

Pipe sizing means choosing the smallest standard pipe that keeps the fluid velocity and the pressure drop inside design limits. A pipe that is too small gives high velocity, noise, erosion and a large pressure drop; a pipe that is too large costs more to buy and install. Both checks are needed — velocity alone, or pressure drop alone, can hide a bad choice.

The two checks

Velocity follows from the flow rate and the flow area of the inside diameter D:

v = Q / (π · D² / 4)

Pressure drop over a straight length L follows from the Darcy–Weisbach equation:

ΔP = f · (L / D) · (ρ · v² / 2)

The friction factor f depends on the Reynolds number and on the relative roughness (pipe roughness divided by D). The Line Sizing calculator uses the Churchill correlation, which covers laminar, transitional and turbulent flow in one expression.

Re = ρ · v · D / μ

Procedure

  1. Collect the flow rate, density, viscosity, pipe length and pipe roughness. Add the equivalent length of fittings and valves to the straight length.
  2. Choose the service and its velocity range and pressure-drop allowance (table below).
  3. Try candidate inside diameters. For each one calculate velocity and pressure drop per 100 m.
  4. Keep the smallest size that is inside the velocity range and below the pressure-drop limit.
  5. If the pressure drop is too high, go up one size; if the velocity falls below the minimum, go down — and accept the compromise you can defend.

Typical liquid design ranges

These are the ranges the calculator offers as design guides. They come from published process design references and are starting points for preliminary sizing, not code requirements — the project specification always governs.

ServiceVelocity (m/s)Pressure drop (bar / 100 m)
Pump suction0.5–1.5≤ 0.05
Pump discharge1.5–3.0≤ 0.5
Header / transfer1.0–2.5≤ 0.3
Cooling water1.5–3.0≤ 0.5
Boiler feed water1.2–2.4≤ 0.45
Drain0.46–1.2–
Gravity flow0.3–0.9≤ 0.02

Worked example — water transfer line

Water at 50 m³/h (density 998 kg/m³, viscosity 1.0 mPa·s) through 100 m of commercial steel pipe (roughness 0.045 mm). The service is a header / transfer line: 1.0–2.5 m/s and no more than 0.3 bar per 100 m. The inside diameters below are trial values.

Inside diameter (mm)Velocity (m/s)Pressure drop (bar / 100 m)
802.760.91
1001.770.295
1251.130.0966
1500.7860.0391

The 80 mm candidate fails both checks (2.76 m/s and 0.91 bar). 100 mm is the smallest that passes: 1.77 m/s and 0.295 bar, just under the 0.3 bar limit. 125 mm passes with margin, while 150 mm falls below the 1.0 m/s minimum (0.786 m/s). In the calculator you pick a nominal size and schedule and the real inside diameter is used.

Run your own numbers — pick a pipe size and see velocity and pressure drop instantly. Open the Line Sizing calculator

More guides

Results are for reference and preliminary checks; a qualified engineer must verify them before use. Read the disclaimer