Vertical and horizontal drum volume and liquid retention time at five levels, with a vessel drawing — in your browser.
The Drum Volume calculator gives the total volume of a vertical or horizontal process drum with 2:1 semi-ellipsoidal heads, and the liquid volume and retention time at each control level. It is used to size separators, knock-out drums, reflux drums and surge drums, and to check that the hold-up between alarm and trip levels meets the process requirement.
The shell volume is π · D² · L / 4 and each 2:1 semi-ellipsoidal head holds π · D³ / 24, with a head depth of one quarter of the internal diameter. In a horizontal drum the wetted cross-section is a circular segment, so liquid volume is not proportional to level; the heads are integrated numerically. Retention time is liquid volume divided by flow rate.
Results are for reference and preliminary checks; a qualified engineer must verify them before use.